Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 18(11): 7688-7710, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38436232

RESUMO

Extracellular matrix (ECM) remodeling is accompanied by the continuous synthesis and degradation of the ECM components. This dynamic process plays an important role in guiding cell adhesion, migration, proliferation, and differentiation, as well as in tissue development, body repair, and maintenance of homeostasis. Nanomaterials, due to their photoelectric and catalytic properties and special structure, have garnered much attention in biomedical fields for use in processes such as tissue engineering and disease treatment. Nanomaterials can reshape the cell microenvironment by changing the synthesis and degradation of ECM-related proteins, thereby indirectly changing the behavior of the surrounding cells. This review focuses on the regulatory role of nanomaterials in the process of cell synthesis of different ECM-related proteins and extracellular protease. We discuss influencing factors and possible related mechanisms of nanomaterials in ECM remodeling, which may provide different insights into the design and development of nanomaterials for the treatment of ECM disorder-related diseases.


Assuntos
Matriz Extracelular , Nanoestruturas , Matriz Extracelular/metabolismo , Proteínas da Matriz Extracelular/análise , Proteínas da Matriz Extracelular/química , Proteínas da Matriz Extracelular/metabolismo , Engenharia Tecidual , Adesão Celular
2.
J Transl Med ; 21(1): 457, 2023 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-37434156

RESUMO

Each step in angiogenesis is regulated by the extracellular matrix (ECM). Accumulating evidence indicates that ageing-related changes in the ECM driven by cellular senescence lead to a reduction in neovascularisation, reduced microvascular density, and an increased risk of tissue ischaemic injury. These changes can lead to health events that have major negative impacts on quality of life and place a significant financial burden on the healthcare system. Elucidating interactions between the ECM and cells during angiogenesis in the context of ageing is neceary to clarify the mechanisms underlying reduced angiogenesis in older adults. In this review, we summarize ageing-related changes in the composition, structure, and function of the ECM and their relevance for angiogenesis. Then, we explore in detail the mechanisms of interaction between the aged ECM and cells during impaired angiogenesis in the older population for the first time, discussing diseases caused by restricted angiogenesis. We also outline several novel pro-angiogenic therapeutic strategies targeting the ECM that can provide new insights into the choice of appropriate treatments for a variety of age-related diseases. Based on the knowledge gathered from recent reports and journal articles, we provide a better understanding of the mechanisms underlying impaired angiogenesis with age and contribute to the development of effective treatments that will enhance quality of life.


Assuntos
Senescência Celular , Qualidade de Vida , Matriz Extracelular , Conhecimento
3.
BMC Oral Health ; 22(1): 580, 2022 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494663

RESUMO

BACKGROUND: This study aimed to evaluate the effect of virtual cement space and restorative materials on the fit of computer-aided design and computer-aided manufacturing (CAD-CAM) endocrowns. METHODS: A mandibular first molar tooth model received a butt joint margin endocrown preparation with a 2-mm occlusal thickness. Then, using a 3D-printing system, 120 copies of this prepared die were printed and assigned equally to three groups with different cement space settings (30, 60, and 120 µm) during the chairside CAD design. In the milling process, CAD-based models with a particular space setting were subdivided into four groups (n = 10) and fabricated from different CAD-CAM materials: Vita Suprinity (VS), Celtra Duo (CD), Lava Ultimate (LU), and Grandio blocs (GR). Finally, the endocrowns were stabilized over their corresponding models with siloxane and subjected to micro-computed tomography to measure the fit. RESULTS: The cement space that was predesigned at 30 µm generated the largest marginal discrepancy (from 144.68 ± 22.43 µm to 174.36 ± 22.78 µm), which was significantly different from those at 60 µm and 120 µm (p < 0.001). The combination of VS or CD with a pre-setting cement space of 60 µm and the combination of LU or GR with a cement space of 120 µm showed better agreement between the predesigned and actual measured marginal gap widths. For internal adaptation, only the cement space set to 30 µm exceeded the clinically acceptable threshold (200 µm). CONCLUSIONS: The setting of the cement space and restorative material significantly affected the marginal adaptation of CAD-CAM endocrown restorations. Considering the discrepancy between design and reality, different virtual cement spaces should be applied to ceramic and resin composite materials.


Assuntos
Adaptação Marginal Dentária , Porcelana Dentária , Humanos , Coroas , Planejamento de Prótese Dentária , Microtomografia por Raio-X , Teste de Materiais , Desenho Assistido por Computador , Materiais Dentários , Cerâmica , Cimentos Dentários , Cimentos de Ionômeros de Vidro
4.
Environ Int ; 164: 107260, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35486964

RESUMO

Benzophenone-type ultraviolet (UV) filters (BPs) are commonly used as sunscreen agents, fragrance enhancers and plastic additives, and are great threats to aquatic organisms due to their high detected concentrations in the aquatic environment. However, few studies on their toxicity and mechanism in fish have been clearly reported. In this study, Chinese rare minnows (Gobiocypris rarus) were exposed to benzophenone (BP), 2,4-dihydroxybenzophenone (BP-1), and 5-benzoyl-4-hydroxy-2-methoxybenzenesulfonic acid (BP-4) at 5, 50, 500 µg/L for 28 d to assess their toxicity. Transcriptomics screening showed that cell cycle, DNA replication and repair were significantly altered pathways (p < 0.05). The altered transcripts were similar to those identified by RNA-seq. DNA damage and 8-OHdG levels were significantly increased at 50 and 500 µg/L groups (p < 0.05). The DNA methylcytosine level was not significantly changed exposure to BP, BP-1 and BP-4. TUNEL assays indicated that hepatic apoptosis was significantly improved at 500 µg/L BP and BP-4 and 50 and 500 µg/L BP-1 (p < 0.05), with the significantly increasing the activity of caspase-3, -8 and -9 (p < 0.05). Molecular docking analysis revealed that BP, BP-1 and BP-4 could bind differently to caspase-3 through different binding interactions. Therefore, BP-1 induced more serious oxidative DNA damage and apoptosis by activating caspase-3 than BP and BP-4, which will provide theoretical basis and data support for ecological evaluation of aquatic organisms induced by BPs.


Assuntos
Cyprinidae , Poluentes Químicos da Água , Animais , Apoptose , Benzofenonas/metabolismo , Caspase 3/metabolismo , China , Cyprinidae/metabolismo , Dano ao DNA , Masculino , Simulação de Acoplamento Molecular , Poluentes Químicos da Água/metabolismo , Poluentes Químicos da Água/toxicidade
5.
BMC Oral Health ; 22(1): 30, 2022 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-35120525

RESUMO

BACKGROUND: This study aimed to evaluate the stress distributions in endocrown restorations as applied to endodontically treated teeth (ETT), according to the factors of "margin design" (four levels) and "restorative material" (six levels). METHODS: Four 3D-finite elements models were constructed for endocrown restored molars considering different margin designs. Model A was prepared with a flat butt joint margin and received an endocrown with a 2.0-mm occlusal thickness. Model B was prepared with a 20° bevel margin and received an endocrown with a 2.0-mm occlusal thickness. Model C was prepared with an axial reduction and 1-mm shoulder margin and received an endocrown with a 2.0-mm occlusal thickness. Model D was prepared with an anatomic margin and received an endocrown with a 2.0-mm occlusal thickness. The following endocrown materials were used: In-Ceram Zirconia (Zr), Vita Suprinity (VS), IPS Empress (IE), Grandio blocs (GR), VisCalor bulk (VS), and CopraPeek Light (CP). The Load application (600 N) was performed at the food bolus and tooth surface during the closing phase of the chewing cycle. The results for the endocrown and tooth remnants were determined according to the von Mises stress. The failure risk of the cement layer was also calculated based on the normal stress criterion. RESULTS: Model D (with an anatomic margin) showed the greatest stress concentrations, especially in the irregular and sharp angles of the restoration and tooth remnants. The stress concentrated on the dentin was significantly lower in Model B with a 20° bevel margin (20.86 MPa), i.e., 1.3 times lower than the other three margin designs (27.80 MPa). Restorative materials with higher elastic moduli present higher stress concentrations inside the endocrown and transmit less stress to the cement layer, resulting in lower bonding failure risks. In contrast, materials with an elastic modulus similar to that of dentin presented with a more homogeneous stress distribution on the whole structure. CONCLUSIONS: An endocrown with a 20° bevel margin design could be a favorable preparation option for ETT. Composite resins (GR and VC) exhibit a more even stress distribution, and seem to be more promising materials for endocrown molars.


Assuntos
Materiais Dentários , Dente não Vital , Resinas Compostas/química , Coroas , Materiais Dentários/química , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Teste de Materiais , Dente Molar
6.
Int J Comput Dent ; 25(3): 267-276, 2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-35072420

RESUMO

AIM: The present in vitro study aimed to evaluate the stress distribution patterns, resistance to fracture, and failure modes of endodontically treated molars restored with different cuspal coverage options. MATERIALS AND METHODS: Three-dimensional models of mandibular first molars with six kinds of typical cuspal coverage were generated: T1: mesiobuccal cuspal coverage; T2: coverage of all buccal cusps; T3: mesiolingual cuspal coverage; T4: coverage of all lingual cusps; T5: mesiobuccal and mesiolingual cuspal coverage; T6: coverage of all cusps. All restorations were fabricated with zirconia-reinforced lithium silicate ceramic. The stress and its distributions under axial and oblique loading were analyzed by finite element analysis (FEA). Sixty human mandibular molar samples were randomly allocated into six groups (n = 10) to simulate the application of six types of restorations with different cuspal coverage, as in the FEA analysis, and were then subjected to a compressive test. All fractured specimens were subjected to fractography. Data were analyzed by one-way analysis of variance (ANOVA), the Tukey post hoc test, and the Fisher exact test (α = 0.05). RESULTS: The T2 and T6 groups presented superior stress distribution patterns under both axial and oblique loading compared with the other models. The fracture loads in the T2 (1627 ± 358 N) and T6 (1639 ± 355 N) groups were significantly higher than those in the other groups (P < 0.05). The T2 and T6 groups exhibited more restorable failure modes. Fractography showed more cracks below the cementoenamel junction in the T3, T4, and T5 groups. CONCLUSIONS: Onlay restorations with whole functional cuspal coverage provided comparable effects to coverage of all cusps in endodontically treated molars, and both methods exhibited a more even stress distribution and fracture resistance and better mechanical performance in high occlusal areas than other types of cuspal coverage. (Int J Comput Dent 2022;25(3):267-276; doi: 10.3290/j.ijcd.b2599709).


Assuntos
Porcelana Dentária , Lítio , Cerâmica , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Teste de Materiais
7.
BMC Oral Health ; 21(1): 495, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34610825

RESUMO

PURPOSE: This study aimed to evaluate the influence of different types of restorative materials and resin cements on the stress distribution in the regions of the restoration, cement layer and dental remnant in endodontically treated posterior endocrowns. METHODS: A 3D finite element analysis (FEA) model of the first mandibular molar that was restored with an endocrown designed by computer-aided design (CAD) software was generated. Three kinds of restorative materials (Vita Enamic (VE), IPS e.max CAD (EMX) and Grandio blocs (GR)) and two types of cementing materials (NX3 and Maxcem Elite Chroma (MX)) were analysed with such a model. The food layer was also designed before vertical (600 N) forces were applied to simulate physiological masticatory conditions. Thermal expansion was used to simulate the polymerization shrinkage effects of cement layers. The results were obtained by colorimetric graphs of the maximum principal stress in the restoration and tooth remnant. The failure risk of the cement layer was also calculated based on the normal stress. RESULTS: The elastic modulus was positively correlated with the tensile stress peak values in the restoration, mainly at the intaglio surface. However, in the cervical enamel and cement layer, restorative material with a higher elastic modulus generated lower peak stress values. The cement with a higher elastic modulus resulted in higher stress peak values inside the cement layer. The combination of EMX (restorative material) and NX3 (cement material) in the cement layer resulted in the lowest failure risk. SIGNIFICANCE: The ceramic material EMX with a higher elastic modulus appeared to be more effective at protecting the cement layer and residual enamel tissue. Based on the analysis of the failure risk of the cement layer, the combination of EMX and NX3 was recommended as an optional material for endocrowns for endodontically treated posterior teeth.


Assuntos
Materiais Dentários , Cimentos de Ionômeros de Vidro , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Teste de Materiais
8.
Scanning ; 2021: 8320234, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34405033

RESUMO

This study is aimed at comparing the efficacy of heat softening and ultrasonic removal of root-end gutta-percha during retrograde preparation for root apical microsurgery. Recently extracted single-rooted premolars (n = 40) were prepared with standardized endodontically treated and root-end resection and then randomly divided into four groups that received root-end cavity preparation using four different instruments: a diamond-coated ultrasonic tip (AS3D; SACTEON, Paris, France), AS3D with the modified plugger of cordless heat carrier (MSE; B&L Biotech, Bala Cynwyd, PA, USA), stainless steel ultrasonic tip (Jetip-2; B&L Biotech, Bala Cynwyd, PA, USA), or Jetip-2 with MSE. The time required for root-end preparation was recorded. The root apex samples were examined by scanning electron microscopy to assess root surface microcracks and marginal integrity. The remnants of gutta-percha on the cavity walls were evaluated using a stereomicroscope. Statistical analysis was performed using Student's t-test and Wilcoxon rank-sum test (P < 0.05). Usage of MSE with Jetip-2 significantly reduced preparation time from 99.8 ± 6.8 s to 32.4 ± 1.0 s (P = 0.009), the number of microcracks from 42 to 13 (P = 0.036), and the remnants of gutta-percha from 80% to 20% (P = 0.041). Similar results were observed for AS3D with MSE. The heat softening of MSE was effective in cleaning gutta-percha, thus greatly improving the efficiency of the root-end preparation, thereby producing a root-end cavity with fewer microcracks and better marginal integrity.


Assuntos
Guta-Percha , Materiais Restauradores do Canal Radicular , Cavidade Pulpar , Temperatura Alta , Humanos , Microcirurgia , Distribuição Aleatória , Obturação do Canal Radicular , Preparo de Canal Radicular , Ápice Dentário , Ultrassom
9.
J Prosthet Dent ; 125(6): 890-899, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32471627

RESUMO

STATEMENT OF PROBLEM: The performance of endocrowns fabricated with different types of computer-aided design and computer-aided manufacturing (CAD-CAM) materials is unclear. PURPOSE: The purpose of this finite element analysis (FEA) and in vitro study was to compare and evaluate the stress distribution, failure probability, and fracture resistance of endodontically treated teeth restored with endocrowns from CAD-CAM milling blocks including ceramic, polymer-infiltrated ceramic (PICN), and composite resin. MATERIAL AND METHODS: An endodontically treated first mandibular molar restored with an endocrown was modeled by using a CAD software program and imported into an FEA software program. The model was duplicated and received restorations made from CAD-CAM blocks: Vita Suprinity (VS), IPS e.max CAD (EMX), Vita Enamic (VE), Lava Ultimate (LU), and Grandio blocs (GR). Stress distributions under axial and oblique loading were analyzed. The Weibull function was combined with the FEA results to predict long-term failure probability. The mechanical failure behavior of endocrowns manufactured with these materials was tested by using a universal testing machine. Load-to-failure was recorded, and fractured specimens were subjected to fractography. The data were analyzed by 1-way ANOVA and the post hoc Tukey test (α=.05). RESULTS: The models of GR and LU exhibited a more even stress distribution. The Weibull analysis revealed that 5 models performed in a similar manner under normal occlusal forces, while LU and VE models achieved the highest probabilities during clenching. The fracture loads of GR (3808 ±607 N) were significantly higher than those of other materials (P<.05). More favorable failure modes were observed in the GR and VE groups. Fractography showed a greater probability of compression curls and arrest lines in the endocrowns of VE, LU, and GR groups. CONCLUSIONS: When restoring endodontically treated teeth, endocrown fabricated with composite resin exhibited a more uniform stress distribution and higher fracture resistance. More evidence from long-term clinical studies is needed to verify this effect.


Assuntos
Coroas , Porcelana Dentária , Cerâmica , Desenho Assistido por Computador , Análise do Estresse Dentário , Análise de Elementos Finitos , Teste de Materiais
10.
Trials ; 21(1): 559, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32571397

RESUMO

BACKGROUND: Endocrown restoration is widely used to restore endodontically treated teeth. However, the clinical effects of different computer-aided design/computer-aided manufacturing (CAD/CAM) materials for endocrown restoration are not clear. The primary objective of this trial is to compare the clinical efficacy of resin-based bloc and ceramic endocrowns for restoring endodontically treated teeth. METHODS: The proposed resin-based bloc and ceramic endocrown assessment trial is a parallel group-designed randomized controlled trial. We will recruit 156 adults between 18 and 75 years old with a minimum of one such molar. The inclusion criteria were good oral hygiene habits, root apex of molar without evident damage, receipt of standard endodontic treatment, need for endocrown restoration, and only one endocrown restoration performed per patient. Patients participating in another study or those with systemic diseases, disabilities, or known allergies to used materials will be excluded. All patients will be randomized and restored with resin-based bloc and ceramic endocrown according to a random number table. Clinical evaluations will be performed at baseline and after treatment at 6, 12, and 24 months, in accordance with the modified Federation Dentaire Internationale (FDI) criteria, by two independent evaluators. The primary outcome is marginal adaptation; secondary outcomes include wear, tooth integrity, fracture of material and retention, marginal staining, and patient view. All data will be analyzed by an independent statistician. Signed rank-sum tests will be used for intragroup comparisons. Wilcoxon rank-sum tests will be used for intergroup comparisons. Hierarchical logistic regression will be used to adjust the baseline and other important indicators. DISCUSSION: This study will investigate endocrowns of two CAD/CAM materials for endodontically treated molars. The results may help clinicians choose the better CAD/CAM material option and explain to patients the advantages and disadvantages of these two materials with evidence-based support. For patients, the results may lead to improvement in long-term restoration. TRIAL REGISTRATION: ClinicalTrials.gov NCT04033380. Registered on 24 July 2019.


Assuntos
Cerâmica , Resinas Compostas , Coroas , Reparação de Restauração Dentária/métodos , Teste de Materiais/métodos , Adaptação Fisiológica , Adolescente , Adulto , Idoso , China , Desenho Assistido por Computador , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Dente Molar , Satisfação do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...